Existing Building’s Conditions
Table of contents
- Envelope
- Roof
- Exterior Walls
- Window U-value
- Window SC-value
- Window Film
- Infiltration
- Space Use
- Interior Lighting
- Occupancy Control
- Plug Loads
- Plug Loads Control
- Base Process Loads
- Various Process Loads
- Operations
- HVAC Startup
- HVAC Shutdown
- Days of Operation
- # of Floor(s) Conditioned in 24/7
- # of Floor(s) Unlit
- # of Floor(s) Unconditioned
- # of Basement(s) Unconditioned
- Cooling Setpoint Temperature
- Heating Setpoint Temperature
- Cooling Setback Temperature
- Heating Setback Temperature
- DOAS Scheduling
- Air-side
- DX Cooling
- Heat Pump Heating
- Furance Heating
- DX Compressor
- Cooling Supply Air
- Heating Supply Air
- Zone Fan Operation
- Indoor Fan Operation
- Interior Fan Speed
- Min Fan Operation
- Min Airflow Ratio
- Air-side Economizer
- Supply Air Temperature Reset
- Demand Control Ventilation
- Motorized Damper
- Cooling Capacity Optimization
- Heating Capacity Optimization
- Minimum Outside Air
- Exhaust Air
- Heat Source to be changed
- Water-side 1
- Chiller Type
- Chiller Condenser Type
- Chiller Performance
- Chiller Size
- Water-side Economizer
- Cooling Tower Fan Control
- Cooling Tower Pump Head
- Chilled Water Loop Configuration
- Primary CHW Pump Head
- Secondary CHW Pump Head
- Chilled Water Temperature
- Chilled Water Temperature Control
- Water-side 2
- Boiler Type
- Boiler Performance
- Boiler Size
- Hot Water Pump Head
- HW Pump Speed Control
- Hot Water Temperature
- HW Snap Control
- HW Snap Temperature
- Hot Water Temperature Reset
- Solar PV
- Solar PV capacity
- Mount Tilt
The parameters of the existing conditions are captured during the calibration. They are useful to understand a building’s true performance.
Envelope
Roof
Exterior Walls
Window U-value
Window SC-value
Window Film
Infiltration
Space Use
Interior Lighting
Occupancy Control
Plug Loads
Plug Loads Control
Base Process Loads
Various Process Loads
Operations
HVAC Startup
HVAC Shutdown
Days of Operation
# of Floor(s) Conditioned in 24/7
# of Floor(s) Unlit
# of Floor(s) Unconditioned
# of Basement(s) Unconditioned
Cooling Setpoint Temperature
Heating Setpoint Temperature
Cooling Setback Temperature
Heating Setback Temperature
DOAS Scheduling
Air-side
DX Cooling
Heat Pump Heating
Furance Heating
DX Compressor
Cooling Supply Air
Heating Supply Air
Zone Fan Operation
Indoor Fan Operation
Interior Fan Speed
Min Fan Operation
Min Airflow Ratio
Air-side Economizer
Supply Air Temperature Reset
Demand Control Ventilation
Motorized Damper
Cooling Capacity Optimization
Heating Capacity Optimization
Minimum Outside Air
Exhaust Air
Heat Source to be changed
Water-side 1
Chiller Type
Chiller Condenser Type
Chiller Size
Water-side Economizer
Cooling Tower Fan Control
Cooling Tower Pump Head
Chilled Water Loop Configuration
Primary CHW Pump Head
Secondary CHW Pump Head
Chilled Water Temperature
Chilled Water Temperature Control
Water-side 2
Boiler Type
Boiler Size
Hot Water Pump Head
HW Pump Speed Control
Hot Water Temperature
HW Snap Control
HW Snap Temperature
Hot Water Temperature Reset
Solar PV
Solar PV capacity
Mount Tilt