What’s new
Recent changes to InverseAudit.
November 2026
- The actual year’s sun. The calibration and savings tracking calculate each hour’s solar radiation from the meter year’s cloud cover, temperatures, humidity and wind, instead of taking the typical year’s, so heating and cooling follow a cloudier or sunnier year than usual. Recalibrate to use this. See Check inputs and run calibration.
- Benchmarking in the audit report. The InverseAudit report has a Benchmarking section after the Executive summary, with the Benchmarking page’s scores, end uses and analyses. Download PDF on Energy Auditing also has it on its own. The ASHRAE reports don’t include it. See Download a PDF.
- Reminder email to the client’s team. Before tracking starts, the Savings Tracking page sets how often the client’s team gets the savings reminder: Quarterly, Monthly or Off, which stops them all. A person who chose their own on their page keeps it. The building’s owner no longer gets a reminder: the same estimate is on the Savings Tracking page. See Reminder emails.
- More room for the report. On Energy Auditing, › in the Measures panel’s title bar narrows the panel to a strip of its buttons, so the report gets the width; ‹ opens it again. The Site visit tab narrows it by itself. See Measures panel.
- Provided in Items to verify. The ASHRAE report’s Items to verify has a Provided column instead of Entered, for what the owner or operator gave you (drawings, BAS printouts, interviews), and you can type in it. With monthly bills it starts from the Systems dialog. With interval data the operating hours and setpoints start empty, since the calibration finds them from the data; the report no longer prints the starting values as entered. See The site visit questions.
- Lighting and plug load control on weekends. The occupied and unoccupied reductions now follow Days of Operation: Saturday and Sunday are occupied during the HVAC hours only when the building operates then, and Friday keeps its occupied hours until HVAC shutdown. Before, a Monday–Friday building got the occupied reduction on weekend days, so the savings of these two measures change the next time you calculate. The profiles in the Measures panel show the same hours, and on 24/7 floors the plug load profile now shows the occupied reduction too. See Space Use.
- General HVAC questions at Level 1. The ASHRAE report’s Site visit tab asks for the main HVAC system and its heating source at both levels, checked against the model, and at Level 1 for the controls and any HVAC observations. The Facility description has an HVAC table after Space functions. The outside air dampers question is Level 2 only. See Checks against the site visit and the bills.
- Calibration progress. The Progress tab in the Building setup panel shows the calibration’s search as it runs: each simulation’s fit score, the best so far with its CV(RMSE) and NMBE against the Guideline 14 limits, and about how long is left. Every calibration length now ends by refining the best match. See What you’ll see next.
- Equipment totals with hourly data. The Systems dialog’s Equipment totals tab is there for hourly meter data too, for the totals you have from nameplates or drawings. See Systems.
- Furnace Heating in percent. In the Measures panel, the furnace efficiency is a percentage, for example 82, up to 95. See Air-side.
- Monthly bills and daylight saving. With monthly bills, the model keeps its schedules on the same hours all year, without daylight saving. Recalibrate to use this. See Times and daylight saving.
- Savings tracking. After the audit is posted, the Savings Tracking page shows what the selected measures would save with the last 12 months’ actual weather, updated each month, and reminder emails go to the building owner and the client’s team. Once the measures are installed, start tracking and enter each year’s bills: each year is measured against the calibrated model run with that year’s actual weather (IPMVP Option D). See Track savings.
- The Bills dialog has each bill’s Last day of billing period, so the model runs over the bills’ own periods, takes gas in CCF with the bill’s therms per CCF, accepts numbers only, and says why Calculate isn’t available yet. Fill from the bills reads the bill files with AI and puts each bill in the month its period ends. See Enter a year’s bills.
- Savings so far. An open tracking year’s months with bills can be measured before the year is complete, as a preliminary result, with Update so far or by themselves each month. See Savings so far.
- Weather from the 10th. A month’s actual weather is used from the 10th of the next month, when its data is final: for the monthly estimate, Update now, the savings so far and calculating a year. See The weather.
- For clients, a side menu with Home, Benchmarking (read only, with Download PDF), Energy Auditing and Savings Tracking, where they see the potential savings, the measured savings and the bills you enter, read only, and choose how often they get the reminder email. See What clients see.
- Sign in asks “How do you use InverseAudit?” with a card for each role, and the sign-in form shows the choice, with a switch to change it. Google sign-in keeps the choice too. See Sign in and your profile.
- Scores after the retrofit count only their own kind of measure: the asset score the envelope and equipment measures, the operational score the Operations measures. How scores are calculated now explains the three models, what each one changes, the formula with an example, and the scores by end use.
- ASHRAE report checks. Three site visit questions (outside air dampers when unoccupied, the water heater, and at Level 2 the economizer), Differs notes where the model disagrees with the site visit or is below the federal minimum efficiency, the rates against the bills, the causes when gas is above the model, a humidity caution for high setbacks in humid climates, and report checks in the page header. See Checks against the site visit and the bills.
- When a utility isn’t calibrated, the ASHRAE reports say so, for the owner to check, with the bills against the model and the possible causes. Confirmed items under Items to verify print as Modeled, verified. See When a utility isn’t calibrated.
- Archive a building you no longer need in your lists, and bring it back with View archived. See Archive a building.
- Calibration also tries the supply fan’s speed control for single-zone systems, and the economizer’s high limit from 60 °F to 75 °F. See Check inputs and run calibration.
- ASHRAE Level 2 report. On Energy Auditing, choose Report: ASHRAE Level 2 to add the pages ASHRAE Standard 211 asks for a Level 2 audit, including a compliance form, the facility and its systems, an equipment inventory, calibration results and more about each measure. A qualified energy auditor completes them in the new Site visit tab, and the report stays a draft until they’re done. Report: ASHRAE Level 1 gives the Level 1 report, with only the entries Level 1 asks for. See The ASHRAE Level 1 and Level 2 reports.
- One table for each set of figures. The Level 2 report no longer repeats the same figures in two tables: the Analysis section opens with the end uses of every fuel and the End-use breakdown (now with each end use’s peak kW), the cost table gives the material, labor and markup, the savings by measure leave the totals to the QA/QC check, and the Utility analysis is the historical energy use, with the EUI and costs by year only for buildings with several years. See What the report adds.
- Each level’s own measure summary. The Level 2 report no longer has Level 1’s measure summary with Low, Medium and High bands: it has the standard’s Level 2 form with each measure’s figures, at the top of Recommendations, and each measure’s comfort and other non-energy impacts are next to its O&M impact. See Measure text and priorities.
- One measure table in every report PDF. The InverseAudit report’s Recommendations open with the same measure table as the Level 2 report, with each measure’s description, life, ROI and payback, low-cost and capital measures listed apart, and all measures together. The report PDFs no longer print the SIR; the Recommendations tab still shows it. See Reports and PDFs.
- A shorter Level 1 report. The ASHRAE Level 1 report’s Analysis is the baseline’s energy use by end use, and its Recommendations are the measure summary, without InverseAudit’s measure-by-measure results, which are Level 2’s. See What Level 1 leaves out.
- Bill costs in the ASHRAE reports. On the Historical energy use page, a bill without its cost on the meter data gets an estimate at the average rate (the year’s cost ÷ use at the building’s rates), in grey, instead of a blank and a $0 total. The interval data’s estimate and the Annual summary use the same rate. See What the report adds.
- Standard 211 or not. When no program asks for ASHRAE Standard 211, untick This project must meet ASHRAE Standard 211 on the ASHRAE report’s Site visit tab (Compliance page). Every entry becomes optional, the report is never a draft, and it keeps its pages without naming the standard, claiming compliance or printing the compliance form. See If the project doesn’t need to meet Standard 211.
- Report PDFs have one layout: every section’s tables have names on the left and numbers on the right, and the ASHRAE reports’ charts match the rest of the report. Natural gas is orange in every chart, the charts sit centred under their titles, and headings are in sentence case. The cover has no page header or footer, and its statement and signatures sit at the foot of the page. Each file’s name starts with the report type, such as ASHRAE Level 2. For the InverseAudit report, Download PDF also has Appendix B: Carbon impact of measures. See Reports and PDFs.
- Report fixes. Charts in the report PDFs are always printed in full; on a busy server some used to print half-drawn or blank. Appendix A gives the building’s type, the energy data it covers and the calibration’s results, instead of fixed text. An ASHRAE report’s cover isn’t certified while the report is a draft. Report text written from older results, for example before new utility rates, is flagged on the Energy Audit page and when you post. See Calculate, update and post.
- Benchmarking PDF. Download PDF on the Benchmarking page prints the Scores and End uses tabs with every table, chart and analysis. See Understand the benchmark.
- The end-use score tables have a score shading key, on the page and in the PDF, and each fuel keeps its own color in the share of energy cost (electricity blue, natural gas orange). See Scenarios and the energy use gap.
- The Typical Operation Scenario uses the schedules of the ASHRAE Standard 90.1-2007 User’s Manual for the building type, from the next calibration. See How scores are calculated.
- When Benchmarking or Energy Auditing has no building to show, it says why (no building yet, none calibrated, or none pinned) and links to the next step on Home.
- Rates from your bills. The AI bill import reads each bill’s total cost, and each rate becomes the bills’ average cost per unit. Check Inputs warns when a rate you entered is more than 25% off the bills. See Rates.
- Natural gas. The calibration fits the year’s total gas use, so a month the utility skipped and billed with the next one does no harm: enter 0 for it. If your bills are actual meter readings, tick Bills are actual meter readings to compare each month instead. See Meter data.
- Calibration. Hourly calibrations are scored on bias (NMBE) as well as CV(RMSE), as monthly ones are, and gas and fuel bills weigh at most 25% of the score. The search starts from the schedules and setpoints you entered. See Check inputs and run calibration.
- Weather. The calibration uses the meter year’s measured cloud cover and station pressure along with temperatures, and typical-year runs use TMYx 2011-2025 weather from the nearest station (CWEC in Canada). Baselines that already have a TMY3 typical year keep it.
- Time. Meter data, weather and charts are in the building’s local standard time. Interval files recorded in clock time (with daylight saving) are converted automatically, and the model applies daylight saving to its schedules. Recalibrate hourly baselines to use this. See Supported data formats.
- Green Button import reads the file’s units correctly (a 15-minute Wh file used to come in far too large), subtracts solar export from delivered energy, and uses electricity readings only.
- Fuel oil bills are counted in gallons, purchased steam bills now count in the calibration, and chilled water and steam meter data are used in hourly calibrations whenever they’re uploaded.
- A billing year that starts on February 29 now covers the full year.
October 2026
- Benchmarking has two tabs, Scores and End uses, under one bar with the building and Run AI analysis, and each text says whether it is an AI analysis or the Standard text. See Understand the benchmark.
- On Energy Auditing, the ECM Explorer is now the Measures panel, with one key for the colored dots, and the PDFs are under Download PDF at the top. See Run an energy audit and Reports and PDFs.
- Tables have one Export menu (Copy, Print, Excel, PDF); Portfolio also has Columns.
- Each person at a client company has their own Home tab. See What clients see.
- End-Use Benchmarking now opens with the site EUI of the three compared scenarios and a new Energy Use Gap tab. See Scenarios and the energy use gap.
- The Benchmark page shows the model fit as bars, with CV(RMSE) and NMBE against the ASHRAE Guideline 14 limits. See Read the calibration results.
- The ENERGY STAR score uses the modeled floor area and is recalculated automatically when the model changes. See Scores.
- Choose a calibration length: Quick, Standard or Thorough. See Check inputs and run calibration.
- New accounts include a calibrated Demo Building to try the whole workflow. See Quick start with the Demo Building.
- The Recommendations table shows the correct fuel oil, chilled water and steam savings for each measure.
- Saving meter data without changes no longer sends a calibrated baseline back to preparation.
Recently added
- AI utility bill import fills in meter data from your bills and interval data files. See Meter data.
- AI insights explain the benchmark results, and AI-suggested ECMs rate the measures. See AI insights and the Measures panel.
- AI Analyze rewrites the audit report’s text. See Calculate, update and post.
- The ECM Explorer has an Electrification tab for replacing fossil-fuel heating. See ECM parameters.
January 2024
- Monthly meter data is supported.